Did you mean :
HPGe -
thickness of 0.5 mm and a 1 mm thick bottom. The ion implanted contact on the
detector element is negligibly thin compared to 0.5 mm of aluminium so these
detectors have intrinsically good low energy response, allowing spectroscopy down to 20 keV.Because...Products & Services Instruments Multi Channel Analyser - As sample sizes in a QC lab are very small we have chosen a High-Purity Germanium (HPGe) Well
Detector providing high efficiency because the sample is virtually surrounded by active
detector
/en/cataloglight/hpge~f2f2ee0f-57b6-4e12-b924-51abd0272f73
Decade Elite -
Product & Services Instruments Other instruments - For the QC of FDG we strongly suggest the use of an electrochemical
detector. Our
detector is very sensitive, UHPLC & HPLC compatible, has temperature stabilized cell/column compartment, advanced digital filters and a wide section of flow cells.It is fully controlled by Gina and Clarity software and can be integrated in nearly every HPLC system.
/en/cataloglight/decade-elite~76fad59f-d4ed-4182-80e8-e0aa36ee22ea
RAMONA Quattro -
Products & Services Instruments Radio-
Detectors - The RAMONA* Quattro is our ultra sensitive β-HPLC-flow-
detector.RAMONA* Quattro contains 4 beta-radioactivity-coincidence-flow-
detectors in 1 instrument. RAMONA* Quattro applies 4 pairs of 2 x 1 1/8... screen. Each trace shows the same chromatogram slightly delayed. The individual fraction is flowing from the first to the second, third and fourth coincidence
detector and is recorded individually. The flow time from the first to the second, third and
/en/cataloglight/ramona-quattro~9fcaacb6-60ae-4503-8eeb-e68c2c8e5db4
Prep Probe -
rates and radiation result in limited dynamic range with low sensitivity for lower count rates or signal cut-offs with high count rates. Other challenges are the aging of the electronics caused by the strong irradiation and the size of the
detector shielding that has to be installed in a hot cell where available space is limited. To overcome these challenges, we propose the Prep Probe in combination with our GABI Nova. The GABI Nova is a versatile state-of-the-art radio flow
detector. With the Prep
/en/cataloglight/prep-probe~dba2cc38-d580-1276-4d38-39e988fe3265
POMO Nova -
Products & Services Instruments Radio-
Detectors - The POMO Nova is the latest member of our Radio-flow
detector family for Beta +/- emitters for integration in our Radio-HPLC chain. Its high sensitivity for beta+ and Beta- particles makes it the
detector of choice for your Radio pharmacy QC applications. Our high positron efficiency flow cells with low gamma response provide unique detection capabilities for PET isotope studies and ensure low background noise. The POMO Nova is perfectly suited
/en/cataloglight/pomo-nova~06542afd-f178-4836-a588-f92658b81670
QC-Cubicle tracer extension -
Product & Services Turn Key Packages QC-Cubicle extensions - The QC-Cubicle tracer extension can simply be added to the QC-Cubicle. The extension will enlarge the module about 62 cm and create enough space for an additional Radio-HPLC system, working space and storage space. The additional HPLC configured depending on the application with a large range of modules and
detectors.
/en/cataloglight/qc-cubicle-tracer-extension~4475ba73-4725-4ccc-af52-123453fa526a
MIRA Star -
Products & Software Instruments Radio-
Detectors - MIRA Star is a highly sensitive μ-HPLC radioactivity flow
detector. In μ-HPLC-applications the eluate flow rate is very small which optimally requires very small flow cells with almost no dead volume... radioactive fraction is passing one
detector after the other, each coincidence flow
detector is counting separately over the optimal interval time. 4 separate radio-chromatograms are digitally recorded and are displayed on the PC. The flow time from one
/en/cataloglight/mira-star~260ab204-b074-449b-803f-067192a212ba
MiniGITA -
Product & Services Instruments Product & Services Instruments Radio-TLC - MiniGITA* TLC is a scanning device, which moves a radioactivity
detector along 1 trace from start to finish. The repeated, fast, continuous detection from start to finish and... positron
detector based on a small plastic scintillation probe. With this
detector, the instrument can measure medium and high energy beta isotopes like 14[C], 90[Y], 18[F] 11[C] etc. The relative small size and fast respond time of the plastic
/en/cataloglight/minigita~6a58bf99-6d28-42d3-99c4-b3a01b9e1354
PETra -
Products & Services Instruments Gas Chromatography - PETra* consists of GABI*, the radioactivity flow
detector, plus heating for the GC capillary tube between GC oven and scintillation
detector and a 2x2” full crystal scintillation probe with... a high voltage unit for manual or automatic selection of the required
detector operation. Inserting a suitable calibration source and running the automatic calibration program, GABI* sets all parameters to a calibrated energy scale. Recalibration for
/en/cataloglight/petra~ba173cdd-e318-4771-bbd0-b67bd333097b
RITA -
Products & Software Instruments Radio-TLC - RITA Star - the thin layer chromatography radioactivity
detector - uses a linear analyzer
detector, which is sensitive over the entire trace of the chromatogram from start to finish. The input window can.... The Open window Proportional Gas Flow
detector is very suited for low activity Alpha detection. RITA Star has 2 simultaneous sensing electrodes: the delay line determines the location of the counted event; the pulse height of the counting wire is
/en/cataloglight/rita~2ec2c387-4eb6-4d26-afe5-13c8f5a557bb
GABI Nova -
Products & Software Instruments Radio-
Detectors - The GABI Nova is a versatile state-of-the-art radio flow monitor optimally suited for radio flow measurements in nuclear medicine, SPECT or PET laboratories. A large range of
detector probes and flow... GABI directly into the Agilent or the Shimadzu HPLC towers. To obtain the best possible performance for all type of activities and isotopes, it is mandatory to adjust the combination of
detector technology, scintillator, cell volume and shielding to
/en/cataloglight/gabi-nova~98ff052b-15f2-1eb2-0896-39e4589c7990
GITA* -
Products & Services Instruments Radio-TLC - GITA* is a scanning device, which moves the radioactivity
detector along 1 trace from start to finish and goes to the next pre-programmed trace position and scans that trace with individual nuclide... suitable collimator is inserted into the
detector. Simple tools help to keep the distance the same between the sample surface and
detector entry window. GITA* offers a calibration and sensitivity check with a reference source. After all traces of the
/en/cataloglight/gita~669c2dad-d600-4429-aa5f-8e73bc23ca7b
Radio-HPLC -
based on Shimadzu or Agilent HPLC systems and we can deliver a complete line of
detectors including UV, Refractive Index
Detector (RID), Pulse Amperometric
Detector (PAD) and Diode Array
Detector (DAD).Elysia-Raytest devices can be connected to any... different.Elysia-raytest provides different combinations of radio
detectors for PET and SPECT with dedicated HPLC instruments.We have developed special system combinations and modifications to deliver high performance solutions for dedicated applications. We
/en/cataloglight/radio-hplc~5531dd9b-67b0-43da-af76-9ac1a049665c
MARITA Star -
Products & Services Instruments Radio-TLC - MARITA Star – the single trace radioactivity thin-layer-chromatography
detector – applies a linear analyser
detector, which is sensitive over the entire chromatogram trace from start to finish, in other... radiation can be detected with high resolution using a narrow collimator window. MARITA Star can measure a single trace at once. The MARITAStar
detector is elevated after the end of the measurement and a new chromatogram plate can be placed for the
/en/cataloglight/marita-star~2024a086-ba82-4e40-9cec-383b612df646
Inspector -
Product & Services Instruments Environment radiation control - INSPECTOR is a simple, universal, hand-held radioactivity
detector, sensitive for alpha, beta, gamma and x-ray radiation. INSPECTOR has a large end-window Geiger-Mueller counting tube with a window diameter of 45 mm. INSPECTOR has an optical and acoustical event indicator. INSPECTOR can be used as ratemeter or scaler/timer for momentary or long-term measurements. INSPECTOR can display activity in total counts (accumulated in time
/en/cataloglight/inspector~24204c2f-8cd1-497d-90b7-ad02f3f59bb7
Gina Star -
Product & Services Software Chromatography Software - GINA Star is a data acquisition, evaluation, integration and control system for liquid and gas chromatography. Gina Star is the heart of the QC lab control it is able to control the radio-HPLC, all our radio
detectors, our TLC systems the GC and our multichannel analyser. Gina Star has an intuitive graphical user interface with the highest standards compliant to GMP, cGMP, GAMP 5 and 21 CFR part 11 regulations. An audit trail and a user
/en/cataloglight/gina-star~c287e3b0-b312-4c35-95ed-9972eb629ced
Gabi * -
Products & Services Instruments Radio-
Detectors - Gabi* is our radioactivity-HPLC-flow-monitor based on our well proven μ-processor controlled gamma spectrometer technology. GABI* is assembled in modules of 19” format, which make modification and service support very fast and easy. GABI* has a high voltage unit for manual or automatic selection of the required
detector operation. Inserting a suitable calibration source and running the automatic calibration program, GABI* sets all parameters to
/en/cataloglight/gabi~c467bd45-56a6-4499-9cbc-3de109caa915
PAM-170 -
VF - Radiation Protection Actif Radiation Protection Hand-held Radiation Monitoring - Key Features Gasless scintillation
detector Compact, lightweight and resistant design User friendly, ease of use High sensitivity, uniform response Fast selection from stored measurement presets Two settable alarm levels Fast replacement of light-tight foil Optional measurement of the dose rate The PAM-170 series activity meters are portable hand-held instruments intended for the measurement of surface
/en/cataloglight/pam-170~ecb4aaa3-3ccc-bcf0-79c9-3a09b9dc3cad
PAM-100 -
VF - Radiation Protection Actif Radiation Protection Hand-held Radiation Monitoring - A portable handheld device intended for the surface activity measurement of alpha, beta, and gamma radionuclides. Key Features Gasless scintillation
detector Compact, lightweight and resistant design User friendly, ease of use High sensitivity, uniform response Fast selection from stored measurement presets Two settable alarm levels Fast replacement of light-tight foil Optional measurement of the dose rate The
/en/cataloglight/pam-100~335fbfed-1791-2210-fea9-3a09b9d24cb6