Suchen

8 result(s)

PAM-170 -
VF - Strahlenschutz Actives Strahlenschutz Kontamination Monitore - Key Features Gasless scintillation detector Compact, lightweight and resistant design User friendly, ease of use High sensitivity, uniform response Fast selection from stored measurement presets Two settable alarm levels Fast replacement of light-tight foil Optional measurement of the dose rate The PAM-170 series activity meters are portable hand-held instruments intended for the measurement of surface contamination. Models of
/de/cataloglight/pam-170~ecb4aaa3-3ccc-bcf0-79c9-3a09b9dc3cad

Veröffentlichungen
@using FlexoCMS.Modules.Banners.Front.Extensions@{ string menuId = "1,185"; string[] menusIds = menuId.Split(","); int menu1 = int.Parse(menusIds[0]); int menu2 = int.Parse(menusIds[1]); } @if(5 > 0){@Html.VerticalSubMenuWidget(@menu1, @menu2) @Html.BannerWidget("ServicesPages") }Veröffentlichungen David Thonon, Geoffroy Kaisin, Jean Henrottin, Joël Aerts, Hans Van Malderen, André Luxen, Evaluation of an unshielded luminescence flow-through radio-HPLC detector for LC quality control and
/de/publications

RAMONA HPLC LS Pump -
Produkte & Dienstleistungen Geräte Radio-Detectors - Die RAMONA* HPLC-LS-Pumpe ist unsere Flüssig-Szintillator-Mischpumpe, die für die kontinuierliche Beimischung von flüssigem Szintillator für das radioaktive markierte Eluat eines HPLC-Systems verwendet wird. Die RAMONA* HLPC-LS Pumpe ist eine Kolbenpumpe, die für HPLC-Anwendungen geeignet ist. Der Pumpenkörper ist aus rostfreiem Stahl oder alternativ aus Peek gefertigt. Der Kolben ist korrosionsresistent und hochpräzise aus Saphir. Die Ein
/de/cataloglight/ramona-hplc-ls-pump~00936469-45d1-4e6a-bd65-bc563ea68056

PAM-100 -
VF - Strahlenschutz Actives Strahlenschutz Kontamination Monitore - A portable handheld device intended for the surface activity measurement of alpha, beta, and gamma radionuclides. Key Features Gasless scintillation detector Compact, lightweight and resistant design User friendly, ease of use High sensitivity, uniform response Fast selection from stored measurement presets Two settable alarm levels Fast replacement of light-tight foil Optional measurement of the dose rate The PAM-100 series
/de/cataloglight/pam-100~335fbfed-1791-2210-fea9-3a09b9d24cb6

HF-4 -
VF - Strahlenschutz Actives Strahlenschutz Stationäre Dosisleistungsmesssysteme - The HF-4 series hand-foot contamination monitors are intended for the measurement of surface contamination by alpha, beta and gamma emitting radionuclides on hands, feet, and clothing. Key Features Gas-less smart scintillation detectors Optimized number of detectors (two hands, two feet) Two-step measurement of hands (palms and backs) A detachable hand detector for frisking A variety of detectors available for
/de/cataloglight/hf-4~be277dd9-9b6a-526e-31ea-3a09b9f63ed0

Touch Screen Dose Calibrator -
. VDC-606 has CE marking for medical devices and is FDA approved. The heart of every Comecer dose calibrator is the ionization chamber: a completely digital detector that gives a fast and reliable reading.The 100% digital output allows the detector to
/de/cataloglight/touch-screen-dose-calibrator~d96ec635-1d98-e2f8-f150-3a158368e2e4

Gabi * -
Produkte & Dienstleistungen Geräte Radio-Detectors - Gabi* ist unser Radioaktivitäts-HPLC-Durchfluss-Monitor auf Basis unserer bewährten μ-prozessorgesteuerten Gamma-Spektrometer-Technologie. GABI * ist aus 19“ Modulen aufgebaut, die Modifikation und Service-unterstützung sehr schnell und einfach machen. GABI * verfügt über eine Hochspannungseinheit zur manuellen oder automatischen Auswahl des gewünschten Detektorbetriebs. Mit dem Einsetzen einer geeigneten Kalibrierquelle und dem automatische
/de/cataloglight/gabi~c467bd45-56a6-4499-9cbc-3de109caa915

RAMONA Quattro -
Produkte & Dienstleistungen Geräte Radio-Detectors - Die RAMONA* Quattro ist unser ultrahochempfindlicher β-HPLC-Durchfluss-Detektor.RAMONA* Quattro besteht aus 4 Beta-Radioaktivitäts-Koinzidenz-Durchfluss-Detektoren in einem Instrument. RAMONA... einzeln aufgezeichnet. Die Flusszeit vom ersten zum zweiten, dritten und vierten Detektor kann individuell bestimmt werden. Durch die Eingabe der einzelnen Durchflussverzögerung vom ersten zum zweiten, dritten und vierten Detektor im
/de/cataloglight/ramona-quattro~9fcaacb6-60ae-4503-8eeb-e68c2c8e5db4

Contact