Search

17 result(s)

Did you mean :

Decade Elite -
Product & Services Instruments Other instruments - For the QC of FDG we strongly suggest the use of an electrochemical detector. Our detector is very sensitive, UHPLC & HPLC compatible, has temperature stabilized cell/column compartment, advanced digital filters and a wide section of flow cells.It is fully controlled by Gina and Clarity software and can be integrated in nearly every HPLC system.
/en/cataloglight/decade-elite~76fad59f-d4ed-4182-80e8-e0aa36ee22ea

SARA - Smart Automatic Report Analysis -
you want to run your system directly in the lab or if you want to follow the run from your home office. Simply control or generate automatic summary of relevant data from the following systems: GINA X controlled radio-HPLC GINA X controlled radio-TLC GINA X controlled GC GINA X controlled Multi Channel Analyzers pH-Meter (compatible types available on request) Osmolality (compatible types available on request) PTS endotoxin system from Charles River Dose calibrator (compatible types available on
/en/cataloglight/sara-smart-automatic-report-analysis~d5f3d598-42bd-b4fe-5961-39f8af92aaad

Clarity -
acquisition, evaluation and instrument control and is available in a multitude of languages. You can switch any time between English, French, German, Russian, Spanish and Chinese.The portfolio of controlled instruments increases constantly. There are currently more than 470 instruments from various vendors controlled within one environment.Clarity is an advanced Chromatography Data Station (CDS) with optional software modules for data acquisition, processing and instrument control. Its wide range of data
/en/cataloglight/clarity~d510a4ad-a738-4fec-9583-29068b210979

Dose Calibrator iDOSE -
Products & Software Instruments Dose calibrator - iDOSE - SOFTWARE CONTROLLED DOSE CALIBRATOR The iDOSE is a software-controlled ionization chamber, designed for the fast and accurate determination of the activity, the volume activity or the half-life time of radiopharmaceuticals that are used in nuclear medicine for diagnostics and therapy. The dose calibrator is calibrated for all common radionuclides, including the RSO nuclides (Y-90, Er-169, Re-186) and the PET nuclides (e.g. F-18, I-124
/en/cataloglight/dose-calibrator-idose~b31e44e0-581e-51b0-d580-39fa2cbd1330

Safira Sterility Filter Test -
exposing the operator to radiation. SAFIRA can be implemented in existing radiopharmaceutical installations.Up to 3 detection satellites can be controlled by one interface. The stand-alone version can be adapted to any PET synthesizer.
/en/cataloglight/safira-sterility-filter-test~6b6c4cc6-8b82-4125-bff7-6d66121c40ba

Steritest Symbio Pump -
Product & Services Instruments Other instruments - Sterility testing is one of the most crucial steps in pharmaceutical product release. False positives, false negatives, equipment failure and human error can cost you time, money and ultimately your product. The transfer pump is a software controlled peristaltic pump used for the safe, uniform transfer of drug samples from various packaging formats through the sterility testing devices. From a computer, standard operating procedures (SOPs) can
/en/cataloglight/steritest-symbio-pump~635ebe83-8b25-4e55-a8db-49818103fd1f

QC-Cubicle Sample Preparation Module -
-on time. The automatic door opener for the waste makes the work smooth and easy. The preparation module incorporates an integrated TLC plate dryer. This is a unique solution with software controlled drying of your TLC plates and reveals the reference
/en/cataloglight/qc-cubicle-sample-preparation-module~a2dab023-cfb0-4980-a976-fa53a5aed343

Gabi * -
Products & Services Instruments Radio-Detectors - Gabi* is our radioactivity-HPLC-flow-monitor based on our well proven μ-processor controlled gamma spectrometer technology. GABI* is assembled in modules of 19” format, which make modification and service support very fast and easy. GABI* has a high voltage unit for manual or automatic selection of the required detector operation. Inserting a suitable calibration source and running the automatic calibration program, GABI* sets all parameters to
/en/cataloglight/gabi~c467bd45-56a6-4499-9cbc-3de109caa915

Radio-HPLC -
existing HPLC system, either using digital data transfer or an analogue-to-digital converter. Nearly every complete radio-HPLC system can be controlled using one of our software platforms. In addition, we deliver a broad range of different HPLC pumps
/en/cataloglight/radio-hplc~5531dd9b-67b0-43da-af76-9ac1a049665c

MIRA Star -
detectable in a single coincidence flow detector can be obtained by MIRA Star. In PC-controlled HPLC systems, the sensitivity gain can be monitored live and is even more impressive. MIRA Star can be supplied with internal solid scintillators as well as
/en/cataloglight/mira-star~260ab204-b074-449b-803f-067192a212ba

RAPHAELA ACG -
to the local authorities’ requirements and regulations. Each required value of the individual analytical QC instrument will be transferred digitally and automatically controlled, decreasing drastically risk of data miscopying due to human
/en/cataloglight/raphaela-acg~42aede2c-c39f-461c-83cd-003e6e90f74f

PETra -
Products & Services Instruments Gas Chromatography - PETra* consists of GABI*, the radioactivity flow detector, plus heating for the GC capillary tube between GC oven and scintillation detector and a 2x2” full crystal scintillation probe with a special PETra* flow cell. GABI* is the latest technology μ-processor controlled gamma spectrometer with built-in digital rate meter. GABI* is assembled by modules of 19” format, which make modification and service support very fast and easy. GABI* has
/en/cataloglight/petra~ba173cdd-e318-4771-bbd0-b67bd333097b

GABI Nova -
you a perfect documentation of your setup and enhance your GXP tools. Direct control with one of our software solutions ensures a digital signal transfer and a complete integrated solution according to GMP/GLP standards. GABI Nova can be controlled
/en/cataloglight/gabi-nova~98ff052b-15f2-1eb2-0896-39e4589c7990

Prep Probe -
detectability and peak shape. The internal and outer diameters of the loop are also adapted to take into account HPLC flow (from 1 to 250 ml/min). Optionally a downstream 6 positions-valve can be controlled by our software or operator to collect peak of
/en/cataloglight/prep-probe~dba2cc38-d580-1276-4d38-39e988fe3265

ELECTROMECHANICAL ENGINEER (R&D)
Function: We are looking for a versatile R&D electro-mechanical engineer with a substantial experience in electromechanics. Experience in mechanical conception of relatively complex assembly or of automate or machine controlled by computer at destination of qualified users is a plus. You will join a dynamic and fast-paced environment and work with cross-functional teams to develop or improve products in line with the company’s vision and strategy. Key responsabilities: 1. Electromechanical
/en/news/107_electromechanical-engineer-rd

GINA X -
portfolio of controlled instruments increases constantly, and the list of validated instruments is available on our web page.You can simply upgrade your GINA Star to GINA X as older GINA data sets can still be used for evaluations.GINA X is a modular... evaluate older GINA Star data sets or to evaluate data sets generated with instruments controlled by GINA X. It allows you to use and work with GINA measurement files without the need of a connected ELYSIA-RAYTEST detector. It has all the features needed
/en/cataloglight/gina-x~33c3747d-e51a-8d4f-1fa3-39e458ae9d8d

miniGITA Dual -
capability. The miniGITA Dual is directly controlled by our GINA software. The same software can be upgraded to control the radio-HPLC, the GC or the multichannel analyzer, allowing high flexibility, a faster adaptation and a short learning curve
/en/cataloglight/minigita-dual~967c76c8-7dc4-7e17-7f4a-39e4587ddb79

Contact