Search

9 result(s)

Did you mean :

RAMONA Quattro -
individually. The 4 individual chromatograms can be added up and in trace 5 the sum of the 4 individual chromatograms is displayed. The display of the 4 single traces can be suppressed and only the sum shown. Peak-integration can be performed during measurement and displayed live . This procedure improves the sensitivity of the radioactivity-flow-detector-system. While the peaks are growing linearly by 4, the background is adding up to 2 = sqr of 4 only.
/en/cataloglight/ramona-quattro~9fcaacb6-60ae-4503-8eeb-e68c2c8e5db4

GITA* -
first 200 x 200 mm TLC plate are completed, the second TLC-plate can be scanned. A single chromatogram can be displayed live on the screen of the connected PC. Multiple traces can be displayed in 3-dimensional format. Peak integration and evaluation can be performed manually or automatically. The measurement and data handling is digital (single event counting) and limit of detection can be determined for every small peak.
/en/cataloglight/gita~669c2dad-d600-4429-aa5f-8e73bc23ca7b

Prep Probe -
detector, size equivalent to an AA battery, is installed in the lead shielding above an HPLC loop. Our standard loop sizes are: 2, 7 and 16 μl but different loop sizes, up to 1 ml, can be built on demand, depending on the application, to finetune peak detectability and peak shape. The internal and outer diameters of the loop are also adapted to take into account HPLC flow (from 1 to 250 ml/min). Optionally a downstream 6 positions-valve can be controlled by our software or operator to collect peak of
/en/cataloglight/prep-probe~dba2cc38-d580-1276-4d38-39e988fe3265

MiniGITA -
to the following trace and the next TLC can be examined. The chromatogram is displayed life on the screen of the connected PC. Peak integration and evaluation can be performed manually or automatically. The measurement and data handing is digital (single event counting) and the limit of detection can be determined for every small peak.
/en/cataloglight/minigita~6a58bf99-6d28-42d3-99c4-b3a01b9e1354

Gabi * -
happen. Peak integration, background subtraction, flow correction, absolute activity calculation etc. can be performed manually or automatically. Limit-of-detection is determined for every ROI, displayed and printed. GINA* and Clarity programs can
/en/cataloglight/gabi~c467bd45-56a6-4499-9cbc-3de109caa915

RAMONA HPLC LS Pump -
Products & Services Instruments Radio-Detectors - The RAMONA* HPLC-LS pump is our Liquid scintillator admixture pump used for continuous admixture of the liquid scintillator to the radioactive labelled eluate of a HPLC system. The RAMONA* HLPC-LS pump is a piston pump suitable for HPLC applications. The pump body is manufactured in stainless steel or alternatively of peak material.The piston is anticorrosive and highly precisely made of sapphire.The in- and outlet valves are made of Rubin as
/en/cataloglight/ramona-hplc-ls-pump~00936469-45d1-4e6a-bd65-bc563ea68056

MUCHA Nova -
analysis in a centralized SQL Database.MUCHA Nova is dedicated to radionuclides identification during radiopharmaceutical quality control (verification of radioisotope energy peak) and quantitative determination of radio-contaminants coming from cyclotron
/en/cataloglight/mucha-nova~039ace3a-49b8-4312-b730-cc77e3ca812c

PETra -
live on screen. No overriding of ranges can happen. Peak integration, background subtraction, flow correction, absolute activity calculation etc. can be performed manually or automatically. Limit-of-detection is determined for every ROI, displayed
/en/cataloglight/petra~ba173cdd-e318-4771-bbd0-b67bd333097b

GINA X -
and processed. The standard peak information can be depicted in the report (symmetry, resolution, width, area %…) as well as the analytical conditions. The software manages calibration curve, report generation, data export , method creation... for the evaluation of normal radio signals from a GC or a radio-HPLC. It provides a large band of features such as automatic peak detection, half life time correction, background subtraction and automatic report generation. Radio detector control
/en/cataloglight/gina-x~33c3747d-e51a-8d4f-1fa3-39e458ae9d8d

Contact