Did you mean :
Gabi * -
service support very fast and easy. GABI* has a high voltage unit for manual or
automatic selection of the required detector operation. Inserting a suitable calibration source and running the
automatic calibration program, GABI* sets all parameters to a calibrated energy scale. Recalibration for compensation of any drift is easy, fast and fully
automatic. GABI* has 2 simultaneous counting channels with 2 individually selectable energy thresholds each for setting an individual counting window for
/en/cataloglight/gabi~c467bd45-56a6-4499-9cbc-3de109caa915
PETra -
a high voltage unit for manual or
automatic selection of the required detector operation. Inserting a suitable calibration source and running the
automatic calibration program, GABI* sets all parameters to a calibrated energy scale. Recalibration for compensation of any drift is quite easy, fast and fully
automatic. Petra* has 2 simultaneous counting channels with 2 individually selectable energy thresholds, each for setting an individual counting window for a particular nuclide. Petra* counts the
/en/cataloglight/petra~ba173cdd-e318-4771-bbd0-b67bd333097b
GC -
Products & Software Instruments Gas Chromatography - One of the main applications in SPECT and PET laboratories is residual solvent control. One of the advantage of our solution is that the GC system is controllable by the same software as other radio-instruments delivered by Elysia-Raytest.As the injected samples contain radioactivity, we optimize the methods to save time, reduce sample amount and improve radioprotection.All units including the column oven, flow controller and
automatic sample
/en/cataloglight/gc~9650b2a8-4b30-4154-b917-40f3e433cead
GINA X CDS - Centralized Data Solution -
. Integrated Methods and
Automatic Data Transfer are key features to document the whole process complying with the SOP in a GMP environment. GINA X is the heart of your QC laboratory, offering a single software platform to control all your QC instruments... intuitive User Interface renders additional interfaces unnecessary.
Automatic Data Transfer and verification of other QC instruments like endotoxin, pH, osmometry or others is also possible. The centralized solution is based on a SQL database. The
/en/cataloglight/gina-x-cds-centralized-data-solution~1184f072-d33f-86aa-b445-39f9f3d5688f
GAIA V1 -
automatic yield determination- Multiple radio detectors to enhance labelling process and efficiency- Integrated filter integrity test to reduce QC costs- Simple and robust mechanics to reduce down times and maintenance costs- Complete set of validated
/en/cataloglight/gaia-v1~f2b64324-c99b-4d09-8b8e-3de4e44931d1
MUCHA Nova -
parameter selection and operation are performed by touching a soft key on the screen. Every screen offers all operational functions as needed for the analysis to be performed. Display of the measured spectrum is live. Periodic
automatic energy calibration is obtained by using a suitable Cs-137 calibration source. Extended calibration through a suitable multi-nuclides source is also possible.Selected nuclides are named with the activity unit. Background spectra can be accumulated and
automatically
/en/cataloglight/mucha-nova~039ace3a-49b8-4312-b730-cc77e3ca812c
miniGITA Single -
. Simply change the detector/probe and the system will recognize the type and the serial number of your detector.You can even use the probes with and from our radio-flow monitor GABI Nova.This
automatic probe recognition will give you a perfect.... Collimators To avoid human mistakes and to obtain the best collimation, the miniGita Single has tungsten collimators with an
automatic recognition for GMP documentation.miniGITA Single collimator: 0-60 keVminiGITA Single collimator: 60-250 keVminiGITA
/en/cataloglight/minigita-single~8f75bfbe-2ef1-f140-b9e6-39e988c88893
GINA X -
for the evaluation of normal radio signals from a GC or a radio-HPLC. It provides a large band of features such as
automatic peak detection, half life time correction, background subtraction and
automatic report generation. Radio detector control...), quench correction or background subtraction make the difference compared to standard chromatography software. GINA X is also easier to take in hand. The software can record several chromatographic traces that can be manually or
automatically integrated
/en/cataloglight/gina-x~33c3747d-e51a-8d4f-1fa3-39e458ae9d8d
miniGITA Dual -
beta window. Like all miniGITA probes, it uses ECP and can be used in combination with several other Elysia instruments. Collimators To avoid human errors and obtain the best collimation, the miniGITA Dual has tungsten collimators with
automatic... compliant, all settings and configurations are detected
automatically and stored in the electronic report. Probe type, probe distance and even the collimator type are registered. A complete line of probes using different scintillator material, and