Search

9 result(s)

Did you mean :

miniGITA Single -
Products & Software Instruments Products & Software Instruments Radio-TLC - The miniGITA Single is the new version of the well know miniGITA Star. It is a versatile state-of-the-art radio TLC system. The new motor technology reduces considerably the... features, spectrum scan capabilities and a basic half life time mode make the miniGITA Single a versatile system for your quality control lab. Outstanding detection capabilities, excellent signal-to-noise ratio and optimal signal resolution make the
/en/cataloglight/minigita-single~8f75bfbe-2ef1-f140-b9e6-39e988c88893

GAIA -
part of single use kit to avoid cross or bacterial contaminations and to fulfill GMP demands. Thanks to the economized applications of readily available single-use materials, the running costs are minimized.
/en/cataloglight/gaia~8f2e9e3d-2b4e-dedd-f2ca-39e458a23b61

miniGITA Slim -
minute. GxP features, spectrum scan capabilities and a basic half life time mode make the miniGITA Single a versatile system for your quality control lab. Outstanding detection capabilities, excellent signal-to-noise ratio and optimal signal resolution make the miniGITA Single the perfect workhorse for your lab. Testing the radiochemical purity with thin layer chromatography and the execution of basic gamma spectrometry are a routine for many nuclear medicine laboratories and SPECT or PET
/en/cataloglight/minigita-slim~18b8fe68-db1f-6195-d2d3-3a1cac5440b1

GITA* -
first 200 x 200 mm TLC plate are completed, the second TLC-plate can be scanned. A single chromatogram can be displayed live on the screen of the connected PC. Multiple traces can be displayed in 3-dimensional format. Peak integration and evaluation can be performed manually or automatically. The measurement and data handling is digital (single event counting) and limit of detection can be determined for every small peak.
/en/cataloglight/gita~669c2dad-d600-4429-aa5f-8e73bc23ca7b

MARITA Star -
Products & Services Instruments Radio-TLC - MARITA Star – the single trace radioactivity thin-layer-chromatography detector – applies a linear analyser detector, which is sensitive over the entire chromatogram trace from start to finish, in other... radiation can be detected with high resolution using a narrow collimator window. MARITA Star can measure a single trace at once. The MARITAStar detector is elevated after the end of the measurement and a new chromatogram plate can be placed for the
/en/cataloglight/marita-star~2024a086-ba82-4e40-9cec-383b612df646

GINA X CDS - Centralized Data Solution -
. Integrated Methods and Automatic Data Transfer are key features to document the whole process complying with the SOP in a GMP environment. GINA X is the heart of your QC laboratory, offering a single software platform to control all your QC instruments with a unique interface. With the GINA X CDS platform, you are able to control and analyse the data from radio-HPLC’s, all Elysia radio detectors, TLC systems, GC’s, our multichannel analyser and our dose calibrator with a single User Interface. This
/en/cataloglight/gina-x-cds-centralized-data-solution~1184f072-d33f-86aa-b445-39f9f3d5688f

MIRA Star -
detectable in a single coincidence flow detector can be obtained by MIRA Star. In PC-controlled HPLC systems, the sensitivity gain can be monitored live and is even more impressive. MIRA Star can be supplied with internal solid scintillators as well as
/en/cataloglight/mira-star~260ab204-b074-449b-803f-067192a212ba

RAMONA Star -
, simultaneous counting channels are available. Each channel has individual lower and upper discriminators for various applications and calibrations. The integrated microprocessor counts single events in each channel. The number of counts per interval time is
/en/cataloglight/ramona-star~6f7c398c-84cb-4ec0-86c3-89dfe9431fe9

RITA -
used for the electronic collimation. Thus, high energy beta radiation can be detected with high resolution using a narrow collimator window. RITA Star is an extended version of MARITA that can measure automatically many single traces one after the
/en/cataloglight/rita~2ec2c387-4eb6-4d26-afe5-13c8f5a557bb

Contact