Search

10 result(s)

Did you mean :

Inspector -
Product & Services Instruments Environment radiation control - INSPECTOR is a simple, universal, hand-held radioactivity detector, sensitive for alpha, beta, gamma and x-ray radiation. INSPECTOR has a large end-window Geiger-Mueller counting tube with a window diameter of 45 mm. INSPECTOR has an optical and acoustical event indicator. INSPECTOR can be used as ratemeter or scaler/timer for momentary or long-term measurements. INSPECTOR can display activity in total counts (accumulated in time
/en/cataloglight/inspector~24204c2f-8cd1-497d-90b7-ad02f3f59bb7

Gabi * -
a calibrated energy scale. Recalibration for compensation of any drift is easy, fast and fully automatic. GABI* has 2 simultaneous counting channels with 2 individually selectable energy thresholds each for setting an individual counting window for
/en/cataloglight/gabi~c467bd45-56a6-4499-9cbc-3de109caa915

HPGe -
Products & Services Instruments Multi Channel Analyser - As sample sizes in a QC lab are very small we have chosen a High-Purity Germanium (HPGe) Well Detector providing high efficiency because the sample is virtually surrounded by active detector material.The Well detector is fabricated with a blind hole, leaving at least 15 mm of active detector thickness at the bottom of the well and approaching a 4π counting geometry. The Well insert in the endcap is made of aluminium with a side-wall
/en/cataloglight/hpge~f2f2ee0f-57b6-4e12-b924-51abd0272f73

PETra -
compensation of any drift is quite easy, fast and fully automatic. Petra* has 2 simultaneous counting channels with 2 individually selectable energy thresholds, each for setting an individual counting window for a particular nuclide. Petra* counts the
/en/cataloglight/petra~ba173cdd-e318-4771-bbd0-b67bd333097b

MARITA Star -
they produce some Compton electrons. MARITA Star has 2 simultaneous sensing electrodes: the delay line determines the location of the counted event; the pulse height of the counting wire is used for the electronic collimation. Thus, high energy beta... subsequent measurement. The counting gas is a non-inflammable mixture of 90% Argon and 10% Methane, which is traded as P10 gas. Gas consumption is very low. 1 TLC plate of 50 x 200 mm up to 200 x 200 mm can be placed on MARITA Star.
/en/cataloglight/marita-star~2024a086-ba82-4e40-9cec-383b612df646

RITA -
. The Open window Proportional Gas Flow detector is very suited for low activity Alpha detection. RITA Star has 2 simultaneous sensing electrodes: the delay line determines the location of the counted event; the pulse height of the counting wire is... plate. The counting gas is a non-inflammable mixture of 90% Argon and 10% Methane, which is traded as P10 gas. The gas consumption is very low. 2 TLC plates of 200 x 200 mm each can be placed in RITA* at the same time. A metal/glass cover closes RITA
/en/cataloglight/rita~2ec2c387-4eb6-4d26-afe5-13c8f5a557bb

GITA* -
can be performed manually or automatically. The measurement and data handling is digital (single event counting) and limit of detection can be determined for every small peak.
/en/cataloglight/gita~669c2dad-d600-4429-aa5f-8e73bc23ca7b

MIRA Star -
radioactive fraction is passing one detector after the other, each coincidence flow detector is counting separately over the optimal interval time. 4 separate radio-chromatograms are digitally recorded and are displayed on the PC. The flow time from one
/en/cataloglight/mira-star~260ab204-b074-449b-803f-067192a212ba

RAMONA Star -
, simultaneous counting channels are available. Each channel has individual lower and upper discriminators for various applications and calibrations. The integrated microprocessor counts single events in each channel. The number of counts per interval time is
/en/cataloglight/ramona-star~6f7c398c-84cb-4ec0-86c3-89dfe9431fe9

MiniGITA -
(single event counting) and the limit of detection can be determined for every small peak.
/en/cataloglight/minigita~6a58bf99-6d28-42d3-99c4-b3a01b9e1354