miniGITA Dual -
compliant, all settings and configurations are detected automatically and stored in the electronic report. Probe type, probe distance and even the collimator type are registered. A complete line of probes using different scintillator material, and.... Background subtraction, a half-life-time correction and dead time correction are only some features included. Model Application Resolution Dynamic range Multichannel Collimator miniGITA OFA probe SPECT & PET 😃😃😃😃 😃😃😃 😃😃😃 Yes miniGITA PET probe
/en/cataloglight/minigita-dual~967c76c8-7dc4-7e17-7f4a-39e4587ddb79

MiniGITA -
, 250-450, > 450 in keV. Depending on the radiation energy of the radioactive compound, the suitable collimator is inserted into the detector. Simple tools help to keep the distance exactly the same between the sample surface and detector entry... back compensates automatically for the radioactive decay of the compound over the scan length. We provide different detectors and collimators to achieve the best performance according to the customer needs and application. For ß-nuclides we use
/en/cataloglight/minigita~6a58bf99-6d28-42d3-99c4-b3a01b9e1354

miniGITA Single -
. Collimators To avoid human mistakes and to obtain the best collimation, the miniGita Single has tungsten collimators with an automatic recognition for GMP documentation.miniGITA Single collimator: 0-60 keVminiGITA Single collimator: 60-250 keVminiGITA... ECP. The new ECP allows also advanced control and diagnostic of your probes to ensure a better performance and a remote diagnostic. Model Application Resolution Dynamic range Multichannel Collimator miniGITA OFA probe SPECT & PET
/en/cataloglight/minigita-single~8f75bfbe-2ef1-f140-b9e6-39e988c88893

GITA* -
special shape enable a sophisticated design of the scintillation probe. There are 5 mechanical collimators designed for the energy ranges of 0-60, 60-150, 150-250, 250-450, >450 keV. Depending on the radiation energy of the radioactive compound, the suitable collimator is inserted into the detector. Simple tools help to keep the distance the same between the sample surface and detector entry window. GITA* offers a calibration and sensitivity check with a reference source. After all traces of the
/en/cataloglight/gita~669c2dad-d600-4429-aa5f-8e73bc23ca7b

MARITA Star -
radiation can be detected with high resolution using a narrow collimator window. MARITA Star can measure a single trace at once. The MARITAStar detector is elevated after the end of the measurement and a new chromatogram plate can be placed for the
/en/cataloglight/marita-star~2024a086-ba82-4e40-9cec-383b612df646

RITA -
used for the electronic collimation. Thus, high energy beta radiation can be detected with high resolution using a narrow collimator window. RITA Star is an extended version of MARITA that can measure automatically many single traces one after the
/en/cataloglight/rita~2ec2c387-4eb6-4d26-afe5-13c8f5a557bb